top of page

Easy to install. Affordable. Reliable.  
G4X PlugIn ECUs offer the latest in engine management technology, designed to easily maximize the potential from your car.  
This ECU fits inside the factory OEM enclosure. Installation is a breeze, with no alteration of the factory wiring loom required for the models listed below. 

Designed for the 2JZ non VVTi engine.   
 

  • Please check your connector matches the header in the listed photo before purchasing.  
  • This ECU works for manual transmissions only.  
  • No onboard MAP sensor. 
  • XS Loom & map sensor highly recommended. 
  • Most factory features are supported. 
  • Check the features tab for I/O expansion options 



Suitable applications:  

Toyota Supra 2JZ non VVTi 

This ECU will support naturally aspirated, parallel twin or single turbo configurations.  Does not support sequential control of the stock twin turbos (note: does not fit case of the NA supra)  

SupraLink - TS2JZX Toyota Supra 2jzgte Link G4x ECU

$2,470.00 Regular Price
$2,139.00Sale Price
  • G4X PlugIn Key Features (where applicable):
    Up to 6D fuel and ignition mapping
    Precision closed loop cam control (four cam, independent control)
    Sequential fuel delivery
    Digital triggering, all OEM patterns
    OEM idle hardware supported
    5D boost control with three switchable tables
    Motorsport features - antilag, launch, flat shift
    Continuous barometric correction (on board)
    CAN port
    QuickTune - automated fuel tuning
    Individual cylinder correction
    USB tuning cable included
    Stats recording into on-board memory
    Gear compensations for spark, boost and fuel
    Real time selectable dual fuel, ignition and boost maps
    Sync and crank sensors can be a combination of Hall effect, variable reluctance or optical
    Boost control referenced to gear, speed or throttle position
    512 mega bytes data logging memory
    Staged injection
    Knock with "windowing"

    I/O Expansion Options
    The Toyota Supra plug-in ECU has two expansion connectors. 
    From PCB revision 1.2: 

    Expansion Connector 1::  
    Gnd                Sensor Ground Only  
    +5V Out        Low Current +5V Supply 
    An Volt 7        Analog 0-5V input 
    An Volt 6        Analog 0-5V input 
    An Temp 4        Temperature sensor input 
    An Temp 3        Temperature sensor input 
    DI 8                Digital input 
    DI 7                Digital input 

    Expansion Connector 2  
    Gnd                Sensor Ground Only  
    +5V Out        Low Current +5V Supply 
    Aux 9                EThrottle - can't be used as an Aux Out 
    DI 9                Digital input 
    DI 10                Digital input 
    An Volt 8        Analog 0-5V input 
    An Volt 9        Analog 0-5V input 
    An Volt 10        Analog 0-5V input

bottom of page